Real-time RF exposure setup based on a multiple electrode array (MEA) for electrophysiological recording of neuronal networks

TitoloReal-time RF exposure setup based on a multiple electrode array (MEA) for electrophysiological recording of neuronal networks
Tipo di pubblicazioneArticolo su Rivista peer-reviewed
Anno di Pubblicazione2011
AutoriMerla, Caterina, Ticaud N., Arnaud-Cormos D., Veyret B., and Leveque P.
RivistaIEEE Transactions on Microwave Theory and Techniques
Volume59
Paginazione755-762
Parole chiave1.8 GHz, Absorption, Electromagnetic wave absorption, Electrophysiological recordings, Electrophysiology, Experimental data, Finite difference time domain method, Finite difference time domain simulations, Health risks, Local mean, Magnetic cells, Magnetic domains, Magnetic field effects, Microelectrodes, Multiple electrode arrays, Neural networks, Neuronal activities, Neuronal networks, Nonuniform, Numerical analysis, Numerical results, passive microelectrode array, Radiofrequency spectroscopy, Rating, real-time exposure setup, Recording electrodes, RF fields, Risk assessment, SAR distribution, Scattering parameters, Specific absorption rate, specific absorption rate (SAR) distribution, System efficiency, Telecommunication equipment, Temperature increase, Temperature increment, Temperature measurement, Thermal behaviors
Abstract

Real-time investigations on the effects of mobile-phone exposure on neuronal activity are considered the highest priority in the health risk assessment of RF fields. Therefore, this paper describes a new real-time exposure setup for electrophysiology recordings, combining an open transverse electro-magnetic cell with a multiple electrode array. The system was numerically and experimentally characterized at a frequency of 1.8 GHz, representative of the uplink band of the GSM1800. Finite-difference time-domain simulations were performed, as well as measurements of the S11 scattering parameter and temperature increases for specific absorption rate (SAR) determination. The local mean SAR value near the solution-electrodes interface was evaluated from the temperature measurements and coincided with the simulated one. The same is true for S11 measurements that were consistent with numerical results; hence, confirming the accuracy of the modeling. Nevertheless, nonuniform SAR distributions were observed near the recording electrodes. Good system efficiency was determined from both numerical analysis and experimental data. Thermal behavior was evaluated and a small temperature increment of 0.3 °C for a local experimental SAR of 3.2 W/kg was measured. © 2006 IEEE.

Note

cited By 22

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-79952817200&doi=10.1109%2fTMTT.2010.2100404&partnerID=40&md5=fd4af1e3184d7ca688d31578b9bc77c5
DOI10.1109/TMTT.2010.2100404
Citation KeyMerla2011755