Sorry, you need to enable JavaScript to visit this website.

Interlaboratory indoor ageing of roll-to-roll and spin coated organic photovoltaic devices: Testing the ISOS tests

TitleInterlaboratory indoor ageing of roll-to-roll and spin coated organic photovoltaic devices: Testing the ISOS tests
Publication TypeArticolo su Rivista peer-reviewed
Year of Publication2014
AuthorsGevorgyan, S.A., Corazza M., Madsen M.V., Bardizza G., Pozza A., Müllejans H., Blakesley J.C., Dibb G.F.A., Castro F.A., Trigo J.F., Guillén C.M., Herrero J.R., Morvillo Pasquale, Maglione Maria Grazia, Minarini Carla, Roca F., Cros S., Seraine C., Law C.H., Tuladhar P.S., Durrant J.R., and Krebs F.C.
JournalPolymer Degradation and Stability
Volume109
Pagination162-170
KeywordsConvergence of numerical methods, Degradation, Interlaboratory studies, Lifetime reporting, Organic photovoltaic (OPV), Organic photovoltaic devices, Organic photovoltaics, Reproducibilities, Roll to Roll, Spin glass, Stability performance, Testing conditions
Abstract

The inter-comparability of ageing of organic photovoltaic (OPV) technologies in dark is addressed. Four primary factors that affect the reproducibility of the ageing rate determination and inter-comparison are discussed: production/encapsulation of the samples, current-voltage (IV) characterization, testing conditions for ageing and lifetime determination from a decay curve. Results of inter-laboratory ageing studies of roll-to-roll and spin coated samples with correspondingly flexible plastic packaging and glass stored in dark conditions among 7 laboratories are presented. ISOS test conditions, proposed recently as guiding protocols for testing OPV stability, are applied in the study. The reproducibility of the performance versus the production and encapsulation techniques is firstly studied. The results reveal a significant improvement in the reproducibility when going from manual spin coating to roll-to-roll production. Furthermore, the reproducibility of current-voltage (IV) measurement and preconditioning (light soaking treatments) are addressed. Additionally, the inter-comparison of the degradation rates of the samples aged under three different dark test conditions (ambient, dry/heat, damp heat) reported by different groups are analyzed revealing a reasonable agreement. Finally, a logarithmic diagram for OPV lifetime associated with common time units is proposed that allows conveniently categorizing and intercomparing the stability performance of different samples aged under different test conditions. © 2014 Elsevier Ltd. All rights reserved.

Notes

cited By 10

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84907325812&doi=10.1016%2fj.polymdegradstab.2014.07.013&partnerID=40&md5=fea3e7018e8c13aa180be1ea2928c27a
DOI10.1016/j.polymdegradstab.2014.07.013
Citation KeyGevorgyan2014162