Sorry, you need to enable JavaScript to visit this website.

Retrofitting of complex wooden structures by means of mixed reversible technologies: A study case

TitleRetrofitting of complex wooden structures by means of mixed reversible technologies: A study case
Publication TypePresentazione a Congresso
Year of Publication2005
AuthorsFaggiano, B., Marzo Anna, and Mazzolani F.M.
Conference NameImprovement of Buildings' Structural Quality by New Technologies - Proceedings of the Final Conference of COST Action C12
Conference LocationInnsbruck
Keywords3D models, Complex structure, Mixed-technology, Restoration intervention, Retrofitting, Safety check, Structural retrofitting, Study case, Three dimensional, Wooden buildings, Wooden structure
Abstract

The paper deals with the analysis of the behaviour of complex structures made of ancient wood. With reference to a study case, which is the roofing structures of the Diplomatic Hall of the Royal Palace of Naples, the detailed geometrical and mechanical surveys are shown. On the basis of the results of the structural analysis, by means of a 3D model, the safety checks, accordingtothe EC5 provisions, have identified the capacity of the structure in terms of strength and deformation and then the necessity of a structural retrofitting. Details of the proposed restoration intervention, based on the mixed technologies, are presented. © 2005 Taylor & Francis Group.

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-78650893757&partnerID=40&md5=f76672c3ee190c7fb459529f0a2ecf85