Sorry, you need to enable JavaScript to visit this website.

Simplified and refined methods for seismic vulnerability assessment and retrofitting of an Italian cultural heritage masonry building

TitleSimplified and refined methods for seismic vulnerability assessment and retrofitting of an Italian cultural heritage masonry building
Publication TypeArticolo su Rivista peer-reviewed
Year of Publication2017
AuthorsFormisano, A., and Marzo Anna
JournalComputers and Structures
Volume180
Pagination13-26
ISSN00457949
KeywordsBuildings, Cultural heritages, Damage detection, Earthquakes, Geometrical property, Geophysics, Masonry building, Masonry construction, Masonry materials, Repair, Repairing interventions, Safety factor, Seismic safety factors, Seismic vulnerability, Seismology, Usability check, Vulnerability degree
Abstract

In the paper the usability check and the seismic vulnerability appraisement and repairing of a masonry building with cultural and artistic value located in the Municipality of Cento (Ferrara, Italy) after the last Italian seismic events (Emilia-Romagna, 2012 May 20th and 29th), are reported and discussed. After some indications on the mentioned earthquakes are given, the case study has been presented and useful information on both historical news and geometrical properties have been given. So, the usability check of examined building has been done through the identification of damages occurred under earthquake. Later on, seismic vulnerability assessment of the building on the basis of both the simplified LV1 and the refined LV3 analysis levels given by Italian Guidelines on Cultural Heritage has been performed. The analysis results, compared each other in terms of seismic safety factors, have shown that building has an average vulnerability degree, so to require local repairing and strengthening interventions, which have been herein presented. Finally, the effectiveness of the proposed local interventions has been proved by numerical analysis in the non-linear field. © 2016 Civil-Comp Ltd and Elsevier Ltd

Notes

cited By 23

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84994666184&doi=10.1016%2fj.compstruc.2016.07.005&partnerID=40&md5=2d4ed75d7663bcb1a9ae36d81f3bfe37
DOI10.1016/j.compstruc.2016.07.005
Citation KeyFormisano201713