Sorry, you need to enable JavaScript to visit this website.

DNA fragmentation induced in human fibroblasts by 56Fe ions: Experimental data and monte carlo simulations

TitleDNA fragmentation induced in human fibroblasts by 56Fe ions: Experimental data and monte carlo simulations
Publication TypeArticolo su Rivista peer-reviewed
Year of Publication2009
AuthorsCampa, A., Alloni D., Antonelli Francesca, Ballarini F., Belli M., Dini V., Esposito G., Facoetti A., Friedland W., Furusawa Y., Liotta M., Ottolenghi A., Paretzke H.G., Simone G., Sorrentino E., and Tabocchini M.A.
JournalRadiation Research
Volume171
Pagination438-445
ISSN00337587
Keywordsarticle, Computer simulation, controlled study, DNA, DNA damage, DNA fragmentation, DNA strand breakage, Dose-Response Relationship, fibroblast, Fibroblasts, human, human cell, Humans, ion, Ions, Iron, irradiation, Monte Carlo method, nucleon, priority journal, Radiation, radiation beam, Radiation Dosage, radiation dose, Radiation exposure, radiation response
Abstract

We studied the DNA fragmentation induced in human fibroblasts by iron-ion beams of two different energies: 115 MeV/nucleon and 414 MeV/nucleon. Experimental data were obtained in the fragment size range 15700 kbp; Monte Carlo simulations were performed with the PARTRAC code; data analysis was also performed through the Generalized Broken Stick (GBS) model. The comparison between experimental and simulated data for the number of fragments produced in two different size ranges, 123 kbp and 235700 kbp, gives a satisfactory agreement for both radiation qualities. The Monte Carlo simulations also allow the counting of fragments outside the experimental range: The number of fragments smaller than 1 kbp is large for both beams, although with a strong difference between the two cases. As a consequence, we can compute different RBEs depending on the size range considered for the fragment counting. The PARTRAC evaluation takes into account fragments of all sizes, while the evaluation from the experimental data considers only the fragments in the range of 15700 kbp. When the PARTRAC evaluation is restricted to this range, the agreement between experimental and computed RBE values is again good. When fragments smaller than 1 kbp are also considered, the RBE increases considerably, since γ rays produce a small number of such fragments. The analysis performed with the GBS model proved to be quite sensitive to showing, with a phenomenological single parameter, variations in double-strand break (DSB) correlation. © 2009 The Radiation Research Society.

Notes

cited By 23

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-66149130747&doi=10.1667%2fRR1442.1&partnerID=40&md5=d66795b297d1fcd1ed922cff891f304a
DOI10.1667/RR1442.1
Citation KeyCampa2009438